SDE Split Face Mount Joist Hanger


Select your Model:

SKU: SDE340/30

AUD$475.00per Carton

Description:

The SDE Split Joist Hanger is a two‑piece, width‑adjustable joist hanger that can accommodate joist widths from 60mm and 120mm. Each SDE is comprised of one left and one right piece. It is essential to install nails in the base of the joist hanger to ensure a solid assembly.

Please check Corrosion Information if it is suitable for your application.

Model Variants:

SKUDescriptionUnitCarton QTYPrice AUD
2 PART (LEFT/RIGHT) HEAVY DUTY U HANGERCarton25$475.00
2 PART (LEFT/RIGHT) HEAVY U HANGERCarton25$500.00
2 PART (LEFT/RIGHT) HEAVY DUTY U HANGERCarton25$525.00

Model No Table:

Model No.

Joist Size (mm)

Dimensions (mm)

Fasteners
(No. – Length x Dia., mm)

Country

Design Capacity (kN)

Width

Height

W

H

B

Face

Joist

Uplift

Download

Floor

Roof

SDE340/30

60–120

140–190

30

140

84

22 – 38 x 3.75

16 – 38 x 3.75

AU

k1 = 1.14

k1 = 0.69

k1 = 0.77

11.48

7.82

7.82

NZ

k1 = 1.0

k1 = 0.80

k1 = 0.80

10.80

7.36

7.36

SDE380/30

160–240

30

160

84

22 – 38 x 3.75

16 – 38 x 3.75

AU

k1 = 1.14

k1 = 0.69

k1 = 0.77

11.48

7.82

7.82

NZ

k1 = 1.0

k1 = 0.80

k1 = 0.80

10.80

7.36

7.36

SDE440/30

190–290

30

190

84

28 – 38 x 3.75

20 – 38 x 3.75

AU

k1 = 1.14

k1 = 0.69

k1 = 0.77

17.89

10.50

10.50

NZ

k1 = 1.0

k1 = 0.80

k1 = 0.80

13.95

9.89

9.89

  1. Design Capacity is the lesser of (1) the Characteristic Capacity multiplied by the Australian Capacity Factor, or the NZ Strength Reduction Factor (φ), and applicable the k modification factors following AS 1720.1 and NZS 3603 and (2) the Serviceability Capacity which is the load at 3.2mm joint slip. Design Capacity is the minimum of test data and structural joint calculation.
  2. For Australia, the Capacity Factor (φ) is 0.85 for nails and screws for structural joints in a Category 1 application. Reduce tabulated values where other Category applications govern. For NZ, the Strength Reduction Factor (φ) is 0.80 for nails in lateral loading.
  3. Duration of Load Factor (k1) is as shown. Reduce Duration of Load Factor where applicable. Capacities may not be increased.
  4. Timber species for joint design is seasoned Radiata Pine, which is Australia Joint Group JD4 per AS 1720.1 Table H2.4 and New Zealand Joint Group J5 per NZS 3603 Table 4.1.