LUS Double Shear Joist Hanger


Select your Model:

SKU: LUS46/77Z

AUD$135.00per Carton

Description:

Joist hangers are designed to provide support underneath the joist, rafter or beam to provide a strong a connection. The LUS Double Shear Joist Hanger values engineering at its finest. All hangers in the LUS series have Double-Shear Nailing. This innovation distributes the load through two points on each joist nail for greater strength. It also allows the use of fewer nails, faster installation and the use of standard nails for all connections.

To help with installation speed every LUS Joist Hanger incorporates the Simpson Strong‑Tie Speed Prong feature which is designed to temporarily position and secure the connector for easier and faster installation. 

Please check Corrosion Information if it is suitable for your application.

Model Variants:

SKUDescriptionUnitCarton QTYPrice AUD
46MM X 77MM FACE MOUNT HANGER ZMAXCarton50$135.00
46MM X 77MM FACE MOUNT HANGER SSCarton25$175.00
46MM X 118MM FACE MOUNT HANGER ZMAXCarton50$142.50
46MM X 118MM FACE MOUNT HANGER SSCarton25$250.00
46MM X 166MM FACE MOUNT HANGER ZMAXCarton50$165.00
46MM X 166MM FACE MOUNT HANGER SSCarton25$295.00

Model No Table:

Model No.

Joist Size (mm)

Dimensions (mm)

Fasteners
(No. — Length x Dia., mm)

Design Capacity (kN)

Width

Height

W

H

B

Header6

Joist

Uplift k1 = 1.14

Floor k1 = 0.69

Roof k1 = 0.77

LUS46/ 77Z
LUS46/ 77SS

45

90 – 130

46

77

45

4 — 38 x 3.75

2 — 64 x 3.75

2.3

3.8

4.2

LUS46/ 118Z

LUS46/ 118SS

120 – 190

118

4 — 38 x 3.75

4 — 64 x 3.75

4.6

4.8

5.3

LUS46/ 166Z

LUS46/ 166SS

175 – 280

166

6 — 38 x 3.75

4 — 64 x 3.75

4.6

6.2

6.9

 

  1. Design Capacity is the lesser of (1) the Characteristic Capacity multiplied by the Australian Capacity Factor, and applicable the k modification factors following AS 1720.1 and (2) the Serviceability Capacity which is the load at 3.2 mm joint slip. Design Capacity is the minimum of test data and structural joint calculation.
  2. The Capacity Factor (φ) is 0.85 for nails and screws for structural joints in a Category 1 application. Reduce tabulated values where other Category applications govern.
  3. Duration of Load Factor (k1) is as shown. Reduce Duration of Load Factor where applicable. Capacities may not be increased.
  4. Timber species for joint design is seasoned Radiata Pine, which is Australia Joint Group JD4 per AS 1720.1 Table H2.4.
  5. Uplift loads have been increased for wind or earthquake loading with no further increase allowed. Reduce where other loads govern.
  6. The LUS header nails may be 64 x 3.75 mm nails.
  7. The Design Capacities shall be multiplied by 1.10 when 75 x 3.75 mm nails are used instead of the specified 64 x 3.75 mm nails.
  8. Stainless steel connectors must use SCNR stainless steel ring shank nails.
  9. Nails and Strong-Drive SD Connector screws may not be combined in a connection.