HU Heavy Duty Face Fix Joist Hanger
Select your Model:
SKU: HU140/45
Description:
The HU Face Fix Joist Hanger is a heavy‑duty hanger designed for applications requiring additional strength and safety factors. It is suitable for fixing to timber or masonry.
Please check Corrosion Information if it is suitable for your application.
Model Variants:
| SKU | Description | Unit | Carton QTY | Price AUD |
|---|---|---|---|---|
| Face Mount Joist Hanger 45X140-205mm | Carton | 25 | $93.75 | |
| Face Mount Joist Hanger 45X170-255mm | Carton | 25 | $112.50 | |
| Face Mount Joist Hanger 45X240-355mm | Carton | 25 | $130.00 | |
| Face Mount Joist Hanger 45X285-420mm | Carton | 25 | $140.00 | |
| Face Mount Joist Hanger 63X135-190mm | Carton | 50 | $370.00 | |
| Face Mount Joist Hanger 63X170-250mm | Carton | 25 | $195.00 | |
| Face Mount Joist Hanger 63X225-410mm | Carton | 25 | $207.50 | |
| Face Mount Joist Hanger 63X275-410mm | Carton | 25 | $232.50 | |
| Face Mount Joist Hanger 90X120-180mm | Carton | 50 | $270.00 | |
| Face Mount Joist Hanger 90X160-235mm | Carton | 25 | $155.00 | |
| Face Mount Joist Hanger 90X215-315mm | Carton | 25 | $172.50 | |
| Face Mount Joist Hanger 90X265-390mm | Carton | 25 | $211.25 | |
| Face Mount Joist Hanger 90X305-390mm | Carton | 25 | $290.00 |
Model No Table:
HU Technical Data
|
Model No. |
Markings on Hangers |
Joist Size (mm) |
Dimensions (mm) |
Fasteners |
Design Capacity (kN) |
||||||||
|
Width |
Height |
W |
H |
B |
Thickness |
Timber Header |
Concrete/ Core Filled Blockwork Header |
Joist |
Uplift |
Download |
|||
|
Floor |
Roof |
||||||||||||
|
HU140/ 45 |
HU1.81/ 5 |
45 |
140-205 |
46 |
137 |
64 |
2 |
16 - 38 x 3.75 |
16 - TNT6.4x70 |
6 - 38 x 3.75 |
7.16 |
10.94 |
10.94 |
|
HU170/ 45 |
HU7 |
170-255 |
170 |
16 - 38 x 3.75 |
16 - TNT6.4x70 |
8 - 38 x 3.75 |
8.03 |
10.94 |
10.94 |
||||
|
HU240/ 45 |
HU9 |
240-355 |
237 |
24 - 38 x 3.75 |
24 - TNT6.4x70 |
10 - 38 x 3.75 |
8.03 |
13.8 |
13.8 |
||||
|
HU285/ 45 |
HU11 |
285-420 |
281 |
30 - 38 x 3.75 |
30 - TNT6.4x70 |
10 - 38 x 3.75 |
8.03 |
13.8 |
13.8 |
||||
|
HU135/ 63 |
HU36 |
63 |
135-190 |
65 |
133 |
67 |
8 - 38 x 3.75 |
8 - TNT6.4x70 |
4 - 38 x 3.75 |
5.16 |
6.25 |
6.97 |
|
|
HU170/ 63 |
HU38 |
170-250 |
167 |
10 - 38 x 3.75 |
10 - TNT6.4x70 |
4 - 38 x 3.75 |
5.16 |
7.34 |
8.2 |
||||
|
HU225/ 63 |
HU310 |
225-335 |
225 |
14 - 38 x 3.75 |
14 - TNT6.4x70 |
6 - 38 x 3.75 |
7.16 |
10.11 |
10.31 |
||||
|
HU275/ 63 |
HU312 |
275-410 |
275 |
16 - 38 x 3.75 |
16 - TNT6.4x70 |
6 - 38 x 3.75 |
7.16 |
10.31 |
10.31 |
||||
|
HU120/ 90 |
HU46 |
90 |
120-180 |
90 |
120 |
67 |
12 - 38 x 3.75 |
12 - TNT6.4x70 |
6 - 38 x 3.75 |
5.16 |
8.46 |
8.46 |
|
|
HU155/ 90 |
HU48 |
160-235 |
155 |
14 - 38 x 3.75 |
14 - TNT6.4x70 |
6 - 38 x 3.75 |
5.16 |
9.26 |
9.26 |
||||
|
HU215/ 90 |
HU410 |
215-315 |
213 |
18 - 38 x 3.75 |
18 - TNT6.4x70 |
10 - 38 x 3.75 |
7.55 |
10.94 |
10.94 |
||||
|
HU265/ 90 |
HU412 |
265-390 |
263 |
22 - 38 x 3.75 |
22 - TNT6.4x70 |
10 - 38 x 3.75 |
7.55 |
12.58 |
12.58 |
||||
|
HU305/ 90 |
HU414 |
305-450 |
302 |
24 - 38 x 3.75 |
24 - TNT6.4x70 |
12 - 38 x 3.75 |
7.55 |
13.8 |
13.8 |
||||
- Design Capacity is the lesser of (1) the Characteristic Capacity multiplied by the Australian Capacity Factor, and applicable the k modification factors following AS1720.1 and (2) the Serviceability Capacity which is the load at 3.2mm joint slip. Design Capacity is the minimum of test data and structural joint calculation.
- For Australia, the Capacity Factor (φ) is 0.85 for nails and screws for structural joints in a Category 1 application. Reduce tabulated values where other Category applications govern.
- Duration of Load Factor (k1) is as shown. Reduce Duration of Load Factor (k1) where applicable. Capacities may not be increased.
- Timber species for joint design is seasoned Radiata Pine, which is Australia Joint Group JD4 per AS 1720.1 Table H2.4
- For maximum nailing quantity and load values, fill all round and trianglular holes.
- Concrete shall have a minimum compressive strength of f'c = 18 MPa and concrete core filled blockwork/masonry shall have a minimum compressive strength of f'm =10 MPa.
- Products shall be installed such that Titen Turbo screws are not exposed to the weather.
- Fasteners: Nail dimensions are listed diameter by length. Titen Turbo screws are Simpson Strong-Tie concrete and masonry screws (hex-head model required).