A35 Reinforced Angle Bracket


Select your Model:

SKU: A35

AUD$50.00per Carton

Description:

The versatile A35 Reinforced Angle Brackets provide a way to make a straight angle of 90° connection. The A35 Angle Bracket’s exclusive bending slot allows instant, accurate field bends for two and three-way ties. Balanced, completely reversible design permits the A35 to secure a great variety of connections.

Please check Corrosion Information if it is suitable for your application.

Model Variants:

SKUDescriptionUnitCarton QTYPrice AUD
A34 A35 Reinforced Angle BracketCarton
A34 A35 Reinforced Angle BracketCarton
1 7/16 X 4 1/2" FRAMING ANGLECarton100$50.00
1 7/16 X 4 1/2" FRAMING ANGLE SSCarton25$135.00
1 7/16 X 4 1/2" FRAMING ANGLE ZMAXCarton100$90.00

Model No Table:

Model No.

Dimension (mm)

Type of Connection

Fasteners
(No. – Length x Dia., mm)

Direction of Load

Design Capacity (kN)

Design Capacity (kN)

Australia

New Zealand

W1

W2

Floor
k1 = 0.69

Roof
k1 = 0.77

Wind/ EQ
k1 = 1.14

Floor
k1 = 0.80

Roof
k1 = 0.80

Wind/ EQ
k1 = 1.0

A35Z

35

35

2

9 – 38 x 3.32

A1, E

1.40

1.47

1.47

1.21

1.21

1.38

C1

0.44

0.44

0.44

0.42

0.42

0.42

3

12 – 38 x 3.32

A2

1.40

1.57

1.68

1.21

1.21

1.51

C2

0.86

0.86

0.86

0.81

0.81

0.81

D

1.05

1.05

1.05

0.99

0.99

0.99

4

12 – 38 x 3.32

F1

2.21

2.21

2.21

2.08

2.08

2.08

F27

1.43

1.43

1.43

1.34

1.34

1.34

A35SS

35

35

2

9 – 38 x 3.32

A1, E

0.88

0.88

0.88

0.83

0.83

0.83

C1

0.31

0.31

0.31

0.29

0.29

0.29

3

12 – 38 x 3.32

A2

1.26

1.26

1.26

1.18

1.18

1.18

C2

0.65

0.65

0.65

0.61

0.61

0.61

D

0.84

0.84

0.84

0.79

0.79

0.79

4

12 – 38 x 3.32

F1

1.76

1.76

1.76

1.66

1.66

1.66

F27

1.14

1.14

1.14

1.08

1.08

1.08

  1. Design Capacity is the lesser of (1) the Characteristic Capacity multiplied by the Australian Capacity Factor, or the NZ Strength Reduction Factor (φ), and applicable the k modification factors following AS 1720.1 and NZS 3603 and (2) the Serviceability Capacity which is the load at 3.2mm joint slip. Design Capacity is the minimum of test data and structural joint calculation.
  2. For Australia, the Capacity Factor (φ) is 0.85 for nails and screws for structural joints in a Category 1 application. Reduce tabulated values where other Category applications govern. For NZ, the Strength Reduction Factor (φ) is 0.80 for nails in lateral loading.
  3. Duration of Load Factor (k1) is as shown. Reduce Duration of Load Factor where applicable. Capacities may not be increased.
  4. Timber species for joint design is seasoned Radiata Pine, which is Australia Joint Group JD4 per AS 1720.1 Table H2.4 and New Zealand Joint Group J5 per NZS 3603 Table 4.1.
  5. Design capacities are for one part. When parts are installed on each side of the joist, the minimum joist beadth is 75mm.
  6. Some illustrations show connections that could cause cross–grain tension or bending of the timber during loading if not reinforced sufficiently. In this case, mechanical reinforcement should be considered.
  7. Connectors are required on both sides to achieve F2 load in both directions.
  8. For simultaneous loads in more than one direction, the connector must be evaluated using the Unity Equation. See General Note 'e' on page 15.